产品型号: KYN28A型户内金属铠装抽出式开关设备 |
产品简介: |
|
Switchgear kyn28a - 12 type indoor metal armoured draw out, 3 ~ 10kV three-phase AC 50Hz single bus and single bus section of the complete sets of equipment. | |
产品特点: |
|
Mainly used in power plants, small and medium-sized generator power supply, industrial and mining enterprises and power distribution and power system secondary banished Electric Institute, send electrical and high-voltage motor starting, under control, monitoring and protection, to use. The switch cabinet meet IEC60298, GB3906 standard, can prevent the belt load push-pull circuit breaker handcart, prevent misclassification error closing of circuit breaker, to prevent the grounding switch is in the closed position closed circuit breaker, to prevent mistakenly charged compartment, prevent the charged incorrect closing grounding switch interlocking functions, which can be equipped with abb VD4 vacuum circuit breaker, and can be matched with the Shanghai weiaimu development and manufacturing of VS1+ vacuum circuit breaker. It is a power distribution device with good performance.. | |
产品明细参数: |
|
I. overview Switchgear kyn28a - 12 type indoor metal armoured draw out, 3 ~ 10kV three-phase AC 50Hz single bus and single bus section of the complete sets of equipment. Mainly used in power plants, small and medium-sized generator power supply, industrial and mining enterprises and power distribution and power system secondary banished Electric Institute, send electrical and high-voltage motor starting, under control, monitoring and protection, to use. The switch cabinet meet IEC60298, GB3906 standard, can prevent the belt load push-pull circuit breaker handcart, prevent misclassification error closing of circuit breaker, to prevent the grounding switch is in the closed position closed circuit breaker, to prevent mistakenly charged compartment, prevent the charged incorrect closing grounding switch interlocking functions, which can be equipped with abb VD4 vacuum circuit breaker, and can be matched with the Shanghai weiaimu development and manufacturing of VS1+ vacuum circuit breaker. It is a power distribution device with good performance.. Two, product type and meaning Technical parameters Switch equipment technical parameters Item Company Data Rated voltage KV 7.2, 3.6, 12 Rate constant frequency Hz 50 Rated insulation level 1min power frequency tolerance voltage KV 42 Lightning impulse withstand voltage KV 75 Main generating set current A 1250, 1600, 2000, 2500, 630, 3150 The amount of the branch line is set to flow A 1250, 1600, 2000, 2500, 630, 3150 4S heat stable current (RMS) KA 20, 25, 31.5, 40, 16, 50 Rated dynamic current (Feng Zhi) * KA 50, 63, 80, 100, 40, 125 Guard grade Shell is IP4X, When the door opens, the compartment is IP2X Note: the short-circuit capacity of the current transformer should be considered separately. VS1+, VD4 vacuum circuit breaker technical data Item Single position Data VD4 VS1 Rated voltage KV 7.2, 3.6, 12 Rated insulation The level of 1min power frequency tolerance voltage KV 42 Lightning impulse withstand voltage KV 75 Rate constant frequency Hz 50 Amount constant current A 1250, 1600, 2000, 2500, 630, 3150 Rated symmetrical short-circuit breaking current (RMS) KA 20, 25, 31.5, 40, 16, 50 4S heat stable current (RMS) KA 20, 25, 31.5, 40, 16, 50 Rated dynamic current (peak) KA 50, 63, 80, 100, 40, 125 Mechanical life Time 20000, Rated current 1600~3150A, was 10000 Automatic sequence of operation sequence 0.3s - min - 3 - - - - Non automatic operation sequence of the gate operation 3min - 3min - - - - - - - - - - - cent - When the gate is closed MS < 70 Less than or equal to 100 Time to lock MS Less than or equal to 45 Less than or equal to 50 Between arcing time MS Less than or equal to 15 Less than or equal to 15 Open time MS Less than or equal to 60 Less than or equal to 60 When the circuit breaker is used to control the 3 - 10kV motors, if start-up current of less than 600A must and metal oxide surge arrester, the specific requirements by the user and the factory consultation; when the circuit breaker is used to disconnect the capacitor group, rated current of capacitor group should not greater than 80% of the rated current of the circuit breaker. When the circuit breaker is used to control the 3 - 10kV motors, if start-up current of less than 600A must and metal oxide surge arrester, the specific requirements by the user and the factory consultation; when the circuit breaker is used to disconnect the capacitor group, rated current of capacitor group should not greater than 80% of the rated current of the circuit breaker. Recommended values for action times: Closing time (about 70ms) The opening time is less than 45ms Arcing time (50Hz = 15ms) The breaking time is less than 60ms The minimum duration of the closing command 20ms (100 ms) The minimum instruction duration 40ms (100ms) Note: 1) at the rated voltage of the auxiliary circuit; 2) if the relay contact starts, but failed to break trip coil current. VD4 vacuum breaker spring operating mechanism technical data Rated voltage V Power consumption VA/W1) Storage time (maximum) S2) Communication 110 220 150 150 15 15 Straight Flow 24 30 48 60 110 220 130 130 130 130 140 140 15 15 15 15 15 15 Note: 1) approximate values 2) at the rated voltage VS1+ vacuum breaker spring operating mechanism technical data Serial number Name Single position Quantity 1 Rated operating voltage The closing coil V AC220110 DC220110 Switching coil 2 Coil Power The closing coil W 245 Switching coil 3 Energy storage motor W 70 4 Rated motor voltage V DC220110 5 Rated voltage energy storage time S Less than or equal to 15 6 Normal working voltage range V 85%~110% rated voltage Four. Dimensions and weight. High B (mm) 2300 Width A (mm) The rated current of the sub small bus reaches 1250A thermal stable current 40kA 800 Branch small bus rated current 1600A and above 1000 Deep C (mm) Cable into line 1500 Frame empty into line 1660 Weight (kg) 700 ~ 1200 Five, structure According to the metal clad switchgear in GB3906 enclosed switchgear design. The whole is composed of a cabinet body and a built-in withdrawable part (i.e. truck) two parts. Cabinet body is divided into four separate compartments, shell protection grade IP4X. Each compartment and the circuit breaker room door open door grade IP2X. With the aerial import and export line, cable and other functions of the cable, after the arrangement, can become a variety of power distribution plan Device. From the front to the installation, debugging and maintenance of the switching devices, so it can be formed back to back double array and installed on the wall, to improve the safety and flexibility of the switchgear, the occupation area is reduced. 2.1 shell and other Switch equipment shell is imported aluminum zinc coated steel sheet, by CNC |